Cleanroom Level:FS209E 100-100,000 / ISO 5-8
Brand:YiJing
Place of Manufacture:Wuxi, China
Available Sizes:Customized to Fit your Needs
Dust Removal Rate:99.995%
Bacteria Removal Rate:99.995%
Negative Ion Concentration:50,000/m3
Contact Email:sales@wxyjjhsb.com
Contact Phone:(+86) 159-6178-5588
Price:Contact Us
Product Details


Sterile Laboratories

Applicable Industries: Microbiology, Biomedicine, Biochemistry, Genetic Research

Cleanliness Level: FS209E 100 - 100,000; ISO 5 - 8


Sterile Laboratory Design

Sterile laboratories consist of up to six different sections: prep room, wash room, disinfecting room, sterile room, incubation room, and regular laboratory. The surfaces of these rooms are all smooth and hard; and the instruments within are laid out economically, and are easy to clean and maintain

.  


Sterile Laboratory Disinfection Procedures

(1) Fumigation is a method of complete disinfection that is common in sterile laboratories. Formaldahyde, lactic acid and sulfur may all be used to fumigate sterile laboratories.

(2) A 5% carbolic acid spray can be used in the laboratory to disinfect the air. The spray will also make dust particles and microorganisms fall from the air onto a surface so that they can be wiped away.

(3) UV Lights are another method of disinfection. UV lights should be turned on for 30-60 minutes before each time the laboratory is used.



YiJing Sterile Laboratory Technical Specifications

Laboratory Air Change Rate100,000 Level - 10-15/hour; 10,000 Level 15-25/hour; 1,000 Level 50-52/hour
Workstation Air Speed0.25-0.35 m/s
Pressure DisparityMain Laboratory ≥5Pa compared to adjacent facilities
TemperatureWinter >16℃±2℃;Summer <26℃±2℃
Relative Humidity45-65%
Noise Level≤65dB
Lighting≥300Lux


Additional Information

(1) Changing rooms and main laboratory have air velocity of over 0.3 m/s. Air shower air velocity should be at least 15 m/s. Air pressure disparity between main clean areas and outside areas should be at least 5 Pa. Interior noise level should not exceed 60 db. 

(2)    Level 2 sterile laboratories are 10,000 Level (ISO 7) in all areas, and 100 Level (ISO 5) in workstations and other critical areas.

(3)    The air filtration system for level 2 laboratories includes initial, intermediate, and high-efficiency HEPA filters. These laboratories should employ laminar air flow. Air showers and changing room equipment (sinks, etc.) should all be automatic.

(4)   Level 3 sterile laboratories are similar to level 2 sterile laboratories in many ways, but they have additional purification equipment to ensure an even more sterile environment. Level 3 laboratories have self-leveling epoxy resin floors, and are equipped with electronic door locks, interlocking pass boxes, and equipment for disinfecting pipes in the laboratory. 

(5) Most sterile laboratories are negative pressure environments. The lab itself should have a pressure disparity of 30-40 Pa, while the buffer area should have a disparity of 15-20 Pa.



Sterile Laboratories - Other Equipment

Air Showers, Clean Benches, Pass Boxes, Sampling Booths, Filter Fan Units (FFU), High Efficiency Vents, Cleanroom Doors & Windows


Sterile Laboratory Construction Criteria

(1) All construction materials must meet BSL-1 requirements

(2) Laboratory doors should be equipped with automatic locks and transparent windows

(3) Laboratories should have adequate space dedicated to storage

(4) Laboratory personnel should wear cleanroom apparel and latex gloves at all times

(5) There should be an area to store personal clothing within the laboratory facility

(6) The laboratory facility should be equipped with a high-pressure sterilizer

(7) The laboratory should be equipped with a biosafety cabinet

(8) The laboratory should contain an eyewash station and an emergency sprinkler system

(9) Laboratory exit sign should illuminate in the dark

(10) There should be a reliable power source and emergency lighting so that in case of a power failure, important equipment will still have a power source.




 Selected YiJing Cleanroom Projects

Linqing, China - Linqing People's Hospital Operating Studio

Hangzhou, China - Hangzhou Geological Research Institute, 10,000-Level (ISO 7) Sterile Laboratory

Hefei, China - China Technology University Modern Physics Systems Research Laboratory

Hangzhou, China - Bo Ri Technology Co., PCR Gene Research Laboratory

Guangzhou, China - Guangzhou South China Science and Technology University Inoculation Laboratory

Sizhou, China - Quarantine Bureau Sterile Cleanroom

Taizhou, China - Shan You Plastics, Material Research Laboratory 

Zhengzhou, China - Si Nian Group, Product Quality Testing Laboratory

Zhejiang, China - Ju Hua Group, Material Research Laboratory

Wuxi, China - Chemical Research Institute, 1,000-Level (ISO 6) Sterile Laboratory

Danyang, China - Dan Yao Optics, 10,000-level (ISO 7) Production Facility

Shuozhou, China - Shuozhou Disease Control Center, PCR Laboratory and Cleanroom

Xi'an, China - Fu Shi Da Technology Co., 1,000-level (ISO 6) Laboratory

Urumqi, China - Urumqi Central Hospital, 100-level (ISO 5) Sterile Laboratory

Ningbo, China - Xian An Chemical, 100-level (ISO 5) Sterile Laboratory

——————————————————————————————————————————————————————————————

部分国外客户留影





Position: Home > Cleanrooms > Sterile Laboratories

Open the WeChat "sweep", open the page and click the share button on the top right corner of the screen